Use 10nm wavelength interval to measure the full range of wavelengths from 360nm to 740nm. The dual-beam method and dual-channel sensor array are adopted to achieve high precision and high reproducibility.
Through the viewfinder, you can directly confirm the measurement position.
In addition, a bright white LED light is used to confirm the measurement position of the sample. Compared with the conventional model CM-3600d, the visibility of the viewfinder is significantly improved.
Realize the switch between SCI/SCE through technological innovation, and minimize the movement of components such as filters. The ISO9001 certified quality management system is introduced in the design and product calibration, which makes the products have high reliability and durability.
Despite the built-in 6-inch large integrating sphere, the CM-3600A still has a stylish and compact appearance.
The most appropriate measuring caliber can be selected according to the sample size.
The newly added sample clamp damping reset design makes it difficult to damage the sample. Since it can be kept open at 90°, the positioning of thicker samples becomes simple and easy.
It can measure the middle part of A4 size samples.
Set partitions on both sides of the power switch to prevent accidentally touching the switch.
Use USB communication.
It is an environmentally friendly product that complies with the EU environmental regulations "RoHS Directive" that requires the elimination of hazardous chemical substances.
Simultaneous measurement of SCI and SCE through a special digital gloss control method, continuous measurement can be performed in only 4 seconds. Unlike traditional models, there is no need for frequent mechanical switching between SCI and SCE modes, which improves work efficiency. Since the measurement area does not change when switching modes, stable measurement data can be provided.
The light source that contains UV and the light source that filter out UV emit light sequentially, and the sample data under the light source that contains UV and the sample data under the light source that does not contain UV (400nm or 420nm UV cut filter) can be obtained.
It can also easily obtain data under any light source (UV adjustment). Under any light source, only need to measure the standard fluorescence sample with known spectral reflectance data to complete the UV correction. After UV correction, the sample data under the corresponding light source can be obtained. Since there is no need to adjust the UV for trial and error caused by the movement of the UV cut filter, the measurement time is greatly shortened.
It can measure the reflectance of opaque samples, the transmittance of transparent liquids or solids, and the diffuse transmittance of plastic translucent objects.
Reflection measurement
Comply with JIS, ISO, DIN, CIE, ASTM di: 8°, de: 8° (diffuse lighting, 8° receiving)
Transmission color measurement
Comply with ISO, DIN, CIE, ASTM di:0°, de:0° (diffuse lighting, 0° receiving)
The lighting/receiving system is the same as the traditional model CM-3600d, with data compatibility, so the original CM-3600d users can continue to use the existing database.
It can be operated by Windows system software.