Welcome: ColorSpace 400-886-3881New
Language: 中文|EN

ISO Test Charts

  • ISO standard Siemens single star test chart
  • ISO standard Siemens single star test chart
ISO standard Siemens single star test chartISO standard Siemens single star test chart

ISO standard Siemens single star test chart

  • Brand: ColorSpace
  • Model: CS-TC008-72/144
  • Product description: Reflective Siemens star chart CS-TC008 in 72 and 144 cycles, five print scales from 0.5X to 3X, built to ISO 12233 chart requirements for resolution limit, artefact and radial MTF checks.
  • INQUIRY

CS-TC008 Siemens Star Test Chart (72 / 144 Cycles)

A Siemens star is a set of radial wedges whose width changes continuously along the radius — wide at the rim, narrowing towards the centre. One capture shows resolution limit, artefacts and focus state at the same time. CS-TC008 comes in 72 and 144 cycles and five print scales from 0.5X to 3X, reflective, built to the chart requirements of ISO 12233.

CS-TC008-72 Siemens star chart (72 cycles)

1. What it measures

  • Resolution limit: the radius where the wedges blur together gives the usable spatial frequency.
  • Directional consistency: horizontal, vertical, radial and tangential wedges sit in the same image, so you can compare directions directly.
  • Artefacts: moiré and jaggies appear near the centre, where sharpening, noise reduction or upscaling leave visible traces.
  • Focus and optical axis: the pattern is sensitive to defocus and decentring — asymmetry usually means one or the other.

Compared with a single slanted edge, a star chart does not depend on where the edge lands in frame and is less sensitive to image processing, which makes it a quick check during development. For quantitative SFR curves, pair it with a slanted-edge chart and analysis software.

2. 72 or 144 cycles?

  • 72 cycles: fewer, wider wedges — easier to read and a good fit for mid-resolution systems and coarser detail.
  • 144 cycles: twice the wedges, each about half as wide at the same chart size — aimed at high-resolution cameras and fine detail.
  • Both share the same five print sizes, so fixtures, working distance and lighting can be reused for A/B testing.

CS-TC008-144 Siemens star chart (144 cycles)

3. Specifications

参数

ISO standard Siemens star chart

Model

CS-TC008-72/144

ISO chart scale

0.5X

1X

1.5X

2X

3X

72 cycles

125 × 167 mm
4.92″ × 6.57″

250 × 333.33 mm
9.84″ × 13.11″

375 × 500 mm
14.76″ × 19.66″

500 × 666.67 mm
19.69″ × 26.22″

750 × 1 000 mm
29.53″ × 39.34″

144 cycles

125 × 167 mm
4.92″ × 6.57″

250 × 333.33 mm
9.84″ × 13.11″

375 × 500 mm
14.76″ × 19.66″

500 × 666.67 mm
19.69″ × 26.22″

750 × 1 000 mm
29.53″ × 39.34″

Pattern

Radial wedges (Siemens star) at centre + centre registration mark + corner black/white register blocks and pie marks + grey-scale gradient strips + border on grey background

Type

Reflective

Spectrum

Visible

Standard

ISO 12233:2024 — Digital cameras — Resolution and spatial frequency responses

4. Features

  • MTF variation can be assessed across multiple directions.
  • Sharpness can be measured in the star module of image-quality software such as Imatest.
  • Less sensitive to image processing than slanted-edge eSFR analysis.
  • Built-in design measures to improve test repeatability.
  • Includes low-contrast horizontal and vertical hyperbolic patterns for comparison.
  • Less sensitive to sampling position than a hyperbolic wedge pattern.
  • Sharpness can be read horizontally, vertically, radially and tangentially.
  • Registration marks support automated recognition.

5. How to test

  1. Square the chart to the optical axis, fill the frame and include all four corner marks; light it diffusely and keep specular reflections out.
  2. Lock exposure and white balance, and capture with processing disabled (or recorded) — otherwise artefacts are misread.
  3. Read the radius where the wedges disappear for a visual call; use a star module (e.g. Imatest) for radial MTF or spectral analysis.
  4. Shoot 72 and 144 under identical conditions and compare the same radius to see where the system runs out of high-frequency response.

6. FAQ

Q:What is the difference between 72 and 144 cycles?

A:At the same chart size, 144 cycles doubles the wedge count and roughly halves each wedge, so it covers higher spatial frequencies; 72 cycles is easier to read.

Q:Star, wedge or slanted edge?

A:Star for a fast, multi-directional read including artefacts; wedge for line-side screening; slanted edge plus software for quantitative SFR reporting.

Q:Do I need software?

A:No for a visual trend check; yes for quantitative comparison and reporting.

Q:Which size?

A:0.5X to 3X, from 125 x 167 mm to 750 x 1 000 mm, chosen by field of view and working distance.

Q:Is a transmissive version available?

A:The current model is reflective; transmissive versions for integrating spheres or backlight boxes are quoted per project.

Q:Mounted or unmounted?

A:Mounted charts come with a backing board and frame for direct hanging; unmounted charts suit existing fixtures.

[Book a lab session] For product and test-service enquiries: sales@colorspace.com.cn

ColorSpace WeChat

Follow ColorSpace on WeChat for industry news, events and solutions.

CONTACT US

Contact: sales@colorspace.com.cn

Phone: 15817270587

Tel: configweb_tel

Email: sales@colorspace.com.cn

Add: South Building #2-1101, Lv Di Qi Hang Office Building, Hou Sha Yu, Shun Yi District, Beijing, China

Product & technical supportOpen separately
Scan the qr codeClose
the qr code