  • Product description: ColorSpace CS-TITS-F500D100 Integrated Test System covers ultraviolet, visible, near-infrared, mid- and long-wave infrared, and laser bands. It supports fully automated measurements of NETD, MRTD, MTF
  • INQUIRY

CS-TITS-F500D100 Integrated Visible & Thermal Imaging Test System – Comprehensive End-to-End Performance Evaluation for Multi-Band Electro-Optical Imaging Systems

Independently developed by ColorSpace, the CS-TITS-F500D100 is an integrated system for comprehensive performance evaluation of electro-optical imaging devices. It supports end-to-end testing across UV, visible, NIR, MWIR, LWIR, and laser bands, enabling automated measurement of NETD, MRTD, MTF, SFR, and other critical imaging parameters. Designed for both R&D validation and production line quality control, the system ensures high accuracy, repeatability, and digital traceability.

CS-TITS-F500D100可见及热成像综合测试系统

Infrared thermal imaging technologies are increasingly used in aerospace, defense, UAV inspection, power grid maintenance, automotive night vision, and dual-spectrum fusion cameras. These applications demand higher accuracy, reliability, and data traceability than ever before.
However, conventional testing methods often fall short:

· Manual, fragmented processes slow down workflows

· Test results lack consistency and traceability

· Limited capability to evaluate multi-band imaging systems

The CS-TITS-F500D100 overcomes these challenges with an integrated hardware and software platform. It delivers 1 mK-level precision, fully automated testing, and end-to-end digital data management, ensuring efficient and reliable performance evaluation across multiple spectral bands.
Key Features
Infrared Thermal Imaging Performance Testing

· NETD (Noise Equivalent Temperature Difference)

· MRTD (Minimum Resolvable Temperature Difference)

· MDTD (Minimum Detectable Temperature Difference)

· Uniformity, FPN (Fixed Pattern Noise)

· Imaging Functions: MTF, SITF, ATF, SRF

· Field of View (FOV), Defect/Bad Pixel Detection

Visible & SWIR Testing

· Resolution, SFR, Uniformity, Distortion, SOV

· Defect Detection, Basic Optical Parameter Measurement

Optical System Calibration

· Compatible with reticle targets, blackbody sources, and laser sources

· Optical axis alignment, laser beam expansion

· Ultra-low divergence collimated light output

Application Fields

· Aerospace & Defense: IR seekers, satellite-based thermal imagers

· Power & Industrial Inspection: Drone-based thermal imaging, power line inspection

· Automotive & ADAS: Onboard IR night vision, dual-spectrum fusion cameras

· Research & Manufacturing: Laboratory optical validation, production line quality control

Technical Advantages

· Full Spectrum Coverage: From UV to mid-/long-wave IR, laser compatible

· High-Precision Measurement: Supports NETD testing with 1 mK accuracy

· Automated Data Capture & Analysis: Reduces human error, improves efficiency

· Traceable Data Management: Suitable for both R&D and production, compliant with ISO & GB/T standards

Product Specifications

Specifications
Integrated Visible & Thermal Imaging Test System
Model
CS-TITS-F500D100
Test Items

Visible & SWIR (0.4 μm – 1.4 μm):

SFR, Resolution, Uniformity, Distortion, FOV, SNR, Defect Detection

MWIR & LWIR (4 μm – 15 μm):

MRTD, NETD, MDTD, SFR, MTF, Uniformity, Distortion, FOV, Defect Detection
Collimator
Optical System
Off-axis reflective
Primary Mirror Material

Standard – Quartz

Optional – Zerodur

Focal Length
500mm
Effective Aperture
Φ100 mm
Field of View
3.
Collimation Accuracy
5''
RMS Wavefront Error
≤1/20 λ @632.8 nm
Coating

Standard – Aluminum + Si Protective Layer

Optional – Silver / Gold / Dielectric

Reflectance
≥85%
Weight
30Kg
System Components
Collimator Tube
1 set
CS-F500D100(A) type
Framed Filters
2 pcs

Orange (center wavelength 600 nm)
Green (center wavelength 532 nm)

Framed Attenuator
1 pc
Neutral density filter (430–730 nm)
Framed Reticle
1 set
Crosshair Reticle
Resolution Target Plates: #1 / #2 / #3 / #4 / #5
Star Point Targets: 0.1 / 0.2 / 0.01 / 0.02 / 0.05
Borosilicate Glass Plate
Siemens Star Target

Light Source Module
1 set
CS-175 integrating sphere light source (A-lamp / LED / Laser)
Targets (Custom / Optional)
Infrared Targets
Four-bar, Square, Half-moon, Knife-edge, Cross, Circular aperture, Slit, Contour...
Visible Targets
Resolution target, Half-moon, Knife-edge, Cross, Circular aperture, Slit, Gray contrast...
Hardware Expansion Options
Blackbody
CS-175M
Optical Platform
1m ×1m ×0.8m (LWH)


Related Reading:

1. Infrared Thermal Imager Image Quality Testing Solution


【[Lab Reservation]】For more information about related products and testing services, please contact: sales@colorspace.com.cn

正印科技

Scan the QR code to follow 【ColorSpace】

CONTACT US

Contact: sales@colorspace.com.cn

Phone: 15817270587

Tel: 400-886-3881(周一至周五 9:00~18:00)

Email: sales@colorspace.com.cn

Add: South Building #2-1101, Lv Di Qi Hang Office Building, Hou Sha Yu, Shun Yi District, Beijing, China