The TriAngle® series electronic autocollimators, designed and manufactured by TRIOPTICS Germany, are based on high-resolution CMOS or PSD detectors combined with collimating objectives of various focal lengths. This design provides a very wide measurement range and multiple levels of accuracy to meet diverse application requirements. Depending on the spectral range, the TriAngle® autocollimators are available in UV, visible, and near-infrared versions, enabling measurements across different wavelengths.
Applications
* Measurement of small angular deflections
* Alignment of optical systems
* Alignment of mechanical structures
* Measurement of tilt angles of collimated optical beams
* Measurement of relative tilt between multiple surfaces
* Wedge angle measurement of optical windows
* Measurement of 45° angle errors in right-angle prisms
* Measurement of 90° angle errors in right-angle prisms
* Measurement of rotary table axis wobble
* Measurement of straightness, perpendicularity, and flatness
Key Features
* Supports both relative and absolute measurement modes
* Captures and locates image positions using an area sensor
* A single autocollimator can simultaneously detect and measure up to 12 reflected images
* One PC can control and measure data from up to 12 autocollimators simultaneously
* External trigger function for synchronized measurements
* Real-time image signal and data display
* Powerful software with direct readout, eliminating the need for post-processing calculations
* Multiple user interfaces designed for different applications, offering enhanced usability
* Measurement results can be directly exported in .CSV format for easy storage and analysis
![]()
Product Series and Technical Specifications
· TriAngle® Standard Electronic Autocollimators
Mature, stable, and reliable standard models.
Model |
Focal Length(mm) |
Aperture (mm) | Field of View (arcsec) | Resolution (arcsec) | Repeatability (arcsec) | Accuracy (arcsec) | Light Source | Measurement Frequency |
TA 100-38 | 100 | 26 | 6170×4940 | 0.1 | ±0.25 | ±2.5 |
525nm or 625nmLED |
≥100Hz,(depending on shutter time & conditions) |
TA 150-38 |
150 |
30 | 4120×3300 | 0.07 | ±0.18 | ±1.7 |
≥100Hz,(depending on shutter time & conditions) |
|
TA 200-38 | 200 | 30 | 3090×2470 | 0.05 | ±0.12 | ±1.3 | ||
TA 300-38 |
300 |
30 | 2060×1650 | 0.03 | ±0.08 | ±0.75 | ||
TA 300-57 |
300 |
48 | 2060×1650 | 0.03 | ±0.08 | ±0.75 | ||
TA 500-57 | 500 | 48 | 1240×980 | 0.02 | ±0.03 | ±0.2 | ||
TA 1000-115 | 1000 | 100 | 610×490 | 0.01 | ±0.03 | ±0.2 | ||
TA 1000-140 | 1000 | 125 | 610×490 | 0.01 | ±0.03 | ±0.2 |
· TriAngle® UltraSpec High-Precision Electronic Autocollimators
Equipped with specially designed reticles for ultra-high accuracy within small angular ranges.
Model |
Focal Length(mm) |
Aperture (mm) | Field of View (arcsec) |
Resolution (arcsec) |
Repeatability (arcsec) |
Accuracy (arcsec) | Light Source | Measurement Frequency |
TA US 300-57 | 300 | 45 | 3000×1920 | 0.005 | ±0.03 |
±0.05"(±10”内) ±0.1"(±20”内) ±0.25"(全视场内) |
525nm或 625nm LED |
≥100Hz, (depending on shutter time & conditions) |
TA US 500-57 | 500 | 45 | 1800×1150 | 0.003 | ±0.02 |
±0.05”(±10"内) ±0.1"(±20”内) ±0.25" (全视场内) |
≥100Hz, (depending on shutter time & conditions) |
· TriAngle® Focus Electronic Autocollimators
Adjustable-focus autocollimators that allow beam focusing at different distances, ideal for optical system alignment.
Model |
Focal Length(mm) |
Aperture (mm) | Focusing Range(mm) | Focus Range(m) | Field of View (arcsec) | Resolution (arcsec) | Repeatability(arcsec) | Accuracy(arcsec) |
TAF 100-38±10 | 100 | 18 | ±10 | ±1.00m...∞ | 6170×4940 | 0.1 | ±0.25 | ±2.5 |
TAF 150-38±10 |
150 |
26 | ±10 | ±2.25m...∞ | 4120×3300 | 0.07 | ±0.18 | ±1.7 |
TAF 200-38±10 | 200 | 26 | ±10 | ±4.00m...∞ | 3090×2470 | 0.05 | ±0.12 | ±1.3 |
TAF 300-57±25 |
300 |
48 | ±25 | ±3.60m...∞ | 2060×1650 | 0.03 | ±0.08 | ±0.75 |
TAF 500-57±25 | 500 | 48 | ±25 | ±5.00m...∞ | 1240×980 | 0.02 | ±0.05 | ±0.75 |
TAF 1000-115±50 | 1000 | 100 | ±50 | ±20.0m...∞ | 610×490 | 0.01 | ±0.03 | ±0.2 |
TAF 1000-140±50 | 1000 | 125 | ±50 | ±20.0m...∞ | 610×490 | 0.01 | ±0.03 | ±0.2 |
· TriAngle® LASER Electronic Autocollimators
Equipped with laser light sources for higher power, suitable for long-distance measurements or small reflective surfaces.
Model |
Focal Length(mm) |
Aperture (mm) | Field of View (arcsec) | Resolution (arcsec) | Repeatability (arcsec) | Accuracy (arcsec) | Light Source | Measurement Frequency |
TAL 100-38 | 100 | 26 | 6170×4940 | 0.75 | ±1.5 | ±2.5 |
635nm Laser Diode |
≥100Hz
(depending on shutter time & conditions) |
TAL 150-38 |
150 |
30 | 4120×3300 | 0.5 | ±1.0 | ±1.7 |
≥100Hz (depending on shutter time & conditions) |
|
TAL 200-38 | 200 | 30 | 3090×2470 | 0.35 | ±0.7 | ±1.2 | ||
TAL 300-38 |
300 |
30 | 2060×1650 | 0.25 | ±0.5 | ±0.8 | ||
TAL 300-57 |
300 |
48 | 2060×1650 | 0.25 | ±0.5 | ±0.8 | ||
TAL 500-57 | 500 | 48 | 1240×980 | 0.15 | ±0.3 | ±0.5 | ||
TAL 1000-115 | 1000 | 100 | 610×490 | 0.08 | ±0.15 | ±0.25 | ||
TAL 1000-140 | 1000 | 125 | 610×490 | 0.08 | ±0.15 | ±0.25 |
·TriAngle® NIR Series Near-Infrared Electronic Autocollimators:
Equipped with a near-infrared LED light source and near-infrared detectors, they enable measurements across multiple near-infrared spectra.
Model |
Focal Length(mm) |
Aperture (mm) | Field of View (arcsec) | Resolution (arcsec) | Repeatability (arcsec) | Accuracy (arcsec) | Light Source | Measurement Frequency |
TA NIR 100-38 | 100 | 26 | 6170×4940 | 0.75 | ±1.5 | ±2.5 |
780... 1064nm LED |
≥100Hz
(depending on shutter time & conditions) |
TA NIR 150-38 |
150 |
30 | 4120×3300 | 0.5 | ±1.0 | ±1.7 |
≥100Hz
(depending on shutter time & conditions) |
|
TA NIR 200-38 | 200 | 30 | 3090×2470 | 0.35 | ±0.7 | ±1.2 | ||
TA NIR 300-38 |
300 |
30 | 2060×1650 | 0.25 | ±0.5 | ±0.8 | ||
TA NIR 300-57 |
300 |
48 | 2060×1650 | 0.25 | ±0.5 | ±0.8 | ||
TA NIR 500-57 | 500 | 48 | 1240×980 | 0.15 | ±0.3 | ±0.5 | ||
TA NIR 1000-115 | 1000 | 100 | 610×490 | 0.08 | ±0.15 | ±0.25 | ||
TA NIR 1000-140 | 1000 | 125 | 610×490 | 0.08 | ±0.15 | ±0.25 |
· TriAngle® Large Field Electronic Autocollimators
Featuring an extra-large field of view for extended measurement applications.
Resolution (arcsec)
Model
Focal Length(mm)
Aperture(mm)
Field of View(arcsec)
Repeatability (arcsec)
Accuracy (arcsec)
Light Source
Measurement Frequency
TALF 100-38
100
26
3°×3°
0.1
±0.25"
±3.0”@80%FOV
525nm LED
4Hz
【Reserve a Lab】For more information about related products and testing services, please contact:sales@colorspace.com.cn
Follow ColorSpace for industry n
Contact: sales@colorspace.com.cn
Phone: 15817270587
Tel: 400-886-3881(周一至周五 9:00~18:00)
Email: sales@colorspace.com.cn
Add: South Building #2-1101, Lv Di Qi Hang Office Building, Hou Sha Yu, Shun Yi District, Beijing, China