Medical Charts

  • Fluorescent Indocyanine Green (ICG) Chart
  • Fluorescent Indocyanine Green (ICG) Chart
Fluorescent Indocyanine Green (ICG) ChartFluorescent Indocyanine Green (ICG) Chart

Fluorescent Indocyanine Green (ICG) Chart

  • Brand:Absofi& ColorSpace
  • Product description: Partner with Absofi, ColorSpace now provide a series of test chart specifically for medical and industrial fluorescent endoscope imaging systems.The fluorescent Indocyanine Green (ICG) and Methylene
  • INQUIRY

Fluorescent Indocyanine Green (ICG) Chart is Specifically Designed for Endoscope Imaging Quality Testing _ Complies with TSCGS 313002-2023 Standard Requirements

Partner with Absofi, ColorSpace now provide a series of test chart specifically for medical and industrial fluorescent endoscope imaging systems.The fluorescent Indocyanine Green (ICG) and Methylene Blue Chart ,meets the testing requirements of the TSCGS 313002-2023 standard, to help test and improve image quality of fluorescent imaging system.

Fluorescence technology has also been rapidly developed in the field of in vivo imaging. A typical example is the use of the near-infrared fluorescent dye indocyanine green (ICG) to aid imaging during surgery. ICG, injected into a patient's bloodstream, allows surgeons to see blood flow in tissues or lymph node locations under special near-infrared camera systems, like luminous markers for important structures. ICG fluorescence imaging is now quite common in surgery. To ensure that surgical imaging equipment accurately captures these fluorescence signals, hospitals can use Absofi's ICG fluorescence reference card to calibrate and test the equipment beforehand: before the operation begins, place the reference card in the camera field to check that the bright spots of each concentration gradient can be clearly identified. If the fluorescence of a certain level of brightness is not visible, it indicates that the sensitivity of the equipment may be insufficient or the ambient light interference is too strong and needs to be adjusted. This approach is similar to checking the brightness of the lights before driving at night to ensure that they illuminate the road sufficiently. Similarly, fluorescent reference cards ensure that the "night vision camera" in surgery is reliable and sensitive, and escorts doctors. In addition, these cards can also be used to train medical staff_let beginners intuitively understand the different intensity of fluorescence on the screen, so that they can quickly master the interpretation skills of fluorescence imaging.

ICG Test Chart

ICG Concentration Test Chart


Clinical ICG Chart


Chart Specifications

Parameters Standard Fluorescent Indocyanine Green (ICG) Chart Standard Fluorescent Indocyanine Green (ICG) Chart
Model CS-ECTS-TC25 CS-ECTS-TC28
Size About 8.6 x 5.4 cm (customizable) About 8.6 x 5.4 cm (customizable)
Relevant Standards

TSCGS 313002-2023 standard Medical endoscopy — Endoscopy fluorescence video camera system specifications for image quality evaluation

TSCGS 313002-2023 standard Medical endoscopy — Endoscopy fluorescence video camera system specifications for image quality evaluation
Concentration range

0.03 to 10 micromolar

0.03 to 10 micromolar


【Reserve a Lab】For more information about related products and testing services, please contactsales@colorspace.com.cn

正印科技

Follow [ColorSpace] for industry news/events/solutions

CONTACT US

Contact: sales@colorspace.com.cn

Phone: 15817270587

Tel: 400-886-3881(周一至周五 9:00~18:00)

Email: sales@colorspace.com.cn

Add: South Building #2-1101, Lv Di Qi Hang Office Building, Hou Sha Yu, Shun Yi District, Beijing, China