Medical Charts

  • Medical Endoscopy Test Chart
  • Medical Endoscopy Test Chart
Medical Endoscopy Test ChartMedical Endoscopy Test Chart

Medical Endoscopy Test Chart

  • Brand:ColorSpace
  • Model:ECTS-TC
  • Product description: Medical endoscope test chart for medical endoscope test systems, in line with industry standard testing requirements, (e.g. in line with YY0068.1 standard) can be used to test brightness response func
  • INQUIRY

ECTS-TC series Medical Endoscopy Test Chart——Used with medical endoscope test systems for medical imaging system image quality parameters, in accordance with industry standards (e.g. YY0068.1)

ColorSpace for medical and industrial endoscopic imaging systems,The image quality test system CS-ECTS is specially developed and equipped with the corresponding endoscope test chart (ETCS-TC), which can be used to test and analyze the angular resolution、MTF、spatial frequency、signal-to-noise ratio, color reproduction, AWB、Distortion 、FOV、Shading、Dynamic range、static image latitude/brightness response characteristics、lens spectral transmittance and other parameters. It can be used to test the color and brightness uniformity of the endoscope's own light source with a reflective color test chart.

Meets industry standard requirements such as:

·  YYT/1587:Medical endoscopes-Video endoscopes

·  YYT/1603:Medical endoscopes-Endoscopes supply units-Video camera system

·  YY0068.1:Medical Endoscopes-Rigid Endoscope-Part1:Optical properties and test methods

·  YY 1298:Medical endoscopes-Capsule endoscopes

透射式医疗内窥镜测试卡

ECTS-TC series test charts specifications :

Charts Model Chart Details

1603 chart

(18% grey test chart)

ECTS-TC01 1603 standard test chart (reflective 18% grey chart)
Chart Size:360mm×260mm(Support for customization)
Distance (from chart aperture to light source surface):62mm;

Can be fixed directly to the CS-ECTS test system for use;
With a reflective light source the following items can be tested:
Luminance response function, SNR, tolerance
Pupillary field of view chart ECTS-TC02 Meets YY0068.1 standard for pupillary field of view testing
Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
Can be fixed directly to the CS-ECTS test system for use;

Depth of Field Chart

(Star Chart)

ECTS-TC03

Meets the requirements of the YY0068.1 standard

Can be used to test the depth of field of an endoscope (can also test angular resolution)

Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
Edge Chart ECTS-TC04 Analysis of sharpness and depth of field for FDA approval testing;
Chart contrast ratio 10:1 (contrast ratio can be customised e.g. 4:1, 40:1)

Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
Angular resolution and depth of field Chart ECTS-TC05

JBT 9328-1999 Standard resolution;

YY0068.1 standard compliant for angular resolution testing;

Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
Checkerboard Chart ECTS-TC06 Analyzes distortion and can be used for FDA approval testing;
Checkerboard grid size 1cm (grid size can be customised)
Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
Dot Plot Chart ECTS-TC07 Analyzes optical distortion, lateral chromatic aberration and can be used for FDA approval testing.
Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
Color Accuracy Chart ECTS-TC08 Analysis of parameters such as Color Accuracychromatic aberration can be tested for FDA approval testing.( For camera screens that are circular.)

Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm

24ColorChecker

ECTS-TC09

Analysis of parameters such as Color Accuracychromatic aberration Can be applied to the YY/T1603 standard test.
Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm

Distortion Chart ECTS-TC10 Meets YY0068.1 standard for testing distortion
Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
Uniformity Chart ECTS-TC11

Meets the requirements of YY0068.1 for testing uniformity

Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
Effective luminosity Chart ECTS-TC12 Meets YY0068.1 standard for effective luminosity testing
Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
Can be fixed directly to the CS-ECTS test system for use
FOV Chart ECTS-TC13

For correction of the FOV of the test equipment.

Transmissive chart in glass (customizable reflective)

Chart Size:160 × 134mm

Grey scale Chart(20 levels ECTS-TC14 Grey scale chart for analysis of SNR, Dynamic range, application for FDA approval testing;
20 levels of grey scale (number of grey levels can be customized)

Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
ISO12333 Chart ECTS-TC15 Analyzable test sharpness
Transmissive chart in glass (customizable reflective)
Chart Size:160x134mm
Relative self-effect of illumination light luminosity Chart - Test of relative self-effect of illumination light luminosity according to YY0068.1, to be used with the T-10A instrument


For more information, please contact: sales@colorspace.com.cn


正印科技公众号

Follow ColorSpace for industry news/events/solutions


CONTACT US

Contact: sales@colorspace.com.cn

Phone: 15817270587

Tel: 400-886-3881(周一至周五 9:00~18:00)

Email: sales@colorspace.com.cn

Add: South Building #2-1101, Lv Di Qi Hang Office Building, Hou Sha Yu, Shun Yi District, Beijing, China