ColorSpace for medical and industrial endoscopic imaging systems,The image quality test system CS-ECTS is specially developed and equipped with the corresponding endoscope test chart (ETCS-TC), which can be used to test and analyze the angular resolution、MTF、spatial frequency、signal-to-noise ratio, color reproduction, AWB、Distortion 、FOV、Shading、Dynamic range、static image latitude/brightness response characteristics、lens spectral transmittance and other parameters. It can be used to test the color and brightness uniformity of the endoscope's own light source with a reflective color test chart.
Meets industry standard requirements such as:
· YYT/1587:Medical endoscopes-Video endoscopes
· YYT/1603:Medical endoscopes-Endoscopes supply units-Video camera system
· YY0068.1:Medical Endoscopes-Rigid Endoscope-Part1:Optical properties and test methods
· YY 1298:Medical endoscopes-Capsule endoscopes
ECTS-TC series test charts specifications :
Charts | Model | Chart Details |
1603 chart (18% grey test chart) |
ECTS-TC01 |
1603 standard test chart (reflective 18% grey chart) Chart Size:360mm×260mm(Support for customization) Distance (from chart aperture to light source surface):62mm; Can be fixed directly to the CS-ECTS test system for use; With a reflective light source the following items can be tested: Luminance response function, SNR, tolerance |
Pupillary field of view chart | ECTS-TC02 |
Meets YY0068.1 standard for pupillary field of view testing Transmissive chart in glass (customizable reflective) Chart Size:160x134mm Can be fixed directly to the CS-ECTS test system for use; |
Depth of Field Chart (Star Chart) |
ECTS-TC03 |
Meets the requirements of the YY0068.1 standard Can be used to test the depth of field of an endoscope (can also test angular resolution) Transmissive chart in glass (customizable reflective)Chart Size:160x134mm |
Edge Chart | ECTS-TC04 |
Analysis of sharpness and depth of field for FDA approval testing; Chart contrast ratio 10:1 (contrast ratio can be customised e.g. 4:1, 40:1) Transmissive chart in glass (customizable reflective) Chart Size:160x134mm |
Angular resolution and depth of field Chart | ECTS-TC05 |
JBT 9328-1999 Standard resolution; YY0068.1 standard compliant for angular resolution testing; Transmissive chart in glass (customizable reflective)Chart Size:160x134mm |
Checkerboard Chart | ECTS-TC06 |
Analyzes distortion and can be used for FDA approval testing; Checkerboard grid size 1cm (grid size can be customised) Transmissive chart in glass (customizable reflective) Chart Size:160x134mm |
Dot Plot Chart | ECTS-TC07 |
Analyzes optical distortion, lateral chromatic aberration and can be used for FDA approval testing. Transmissive chart in glass (customizable reflective) Chart Size:160x134mm |
Color Accuracy Chart | ECTS-TC08 |
Analysis of parameters such as Color Accuracy,chromatic aberration can be tested for FDA approval testing.( For camera screens that are circular.)
Transmissive chart in glass (customizable reflective) Chart Size:160x134mm |
24ColorChecker |
ECTS-TC09 |
Analysis of parameters such as Color Accuracy、chromatic aberration Can be applied to the YY/T1603 standard test. |
Distortion Chart | ECTS-TC10 |
Meets YY0068.1 standard for testing distortion Transmissive chart in glass (customizable reflective) Chart Size:160x134mm |
Uniformity Chart | ECTS-TC11 |
Meets the requirements of YY0068.1 for testing uniformity Transmissive chart in glass (customizable reflective)Chart Size:160x134mm |
Effective luminosity Chart | ECTS-TC12 |
Meets YY0068.1 standard for effective luminosity testing Transmissive chart in glass (customizable reflective) Chart Size:160x134mm Can be fixed directly to the CS-ECTS test system for use |
FOV Chart | ECTS-TC13 |
For correction of the FOV of the test equipment. Transmissive chart in glass (customizable reflective) Chart Size:160 × 134mm |
Grey scale Chart(20 levels) | ECTS-TC14 |
Grey scale chart for analysis of SNR, Dynamic range, application for FDA approval testing; 20 levels of grey scale (number of grey levels can be customized) Transmissive chart in glass (customizable reflective) Chart Size:160x134mm |
ISO12333 Chart | ECTS-TC15 |
Analyzable test sharpness Transmissive chart in glass (customizable reflective) Chart Size:160x134mm |
Relative self-effect of illumination light luminosity Chart | - | Test of relative self-effect of illumination light luminosity according to YY0068.1, to be used with the T-10A instrument |
For more information, please contact: sales@colorspace.com.cn